Concepteur de solutions ATEX et industrielles
Contact : +33 (0)4 88 78 21 81

Ex-proof flashing beacon BC150 in GRP

feu atex led xénon zone 1 et 21 en grp

BC150

Beacon in GRP for zone 1, 21

  • ATEX and IEC Ex certified – Zone 1, 2, 21, 22
  • LED version 5W or 10W and Xenon 5J, 10J, 15J and 21J
  • Wide operating temperature range -40 ° to + 70 °
  • 3 finish colors as standard (others on request)
  • High UV resistance
  • Verrine borosilicate red, Yellow (amber), Blue, green, Clear
  • IP66 / 67 protection degree

Customs code: 83311095
Country of origin: FR
Weight: 3.8kg
Stock: Available within 15 days *

Datasheet : beacon BC150 in GRP for zone 1

BC 150 Ex beacon – status light. This beacon is certified for use in  Atex explosive atmosphere, zone 1 & 2 for gas and zone 21 & 22 for dust. It is dedicated for Oil & Gas, chemical, petrochemical, pharmacy industries, marine and Offshore applications. It’s designed for corrosive environnements and hazardous area. The BC150 can also be used as status light. This beacon can be delivered with two different light sources:  Led with steady, rotary, fixed or blinking led of different powers or Flashing with XENON tube of different powers (Four flashing frequencies are selectable). Built in functions: LED type possibility to pilot externally (free voltage contact) 4 différent blinking/rotating frequencies among 36, for Xenon type 4 différent blinking frequencies among 16 can be pilot externally.
Optional it is possible to control the beacon via a telephone line. Housing is in GRP, the lens is  in borosilicate glass.

Specifications

Operating Temperature: T6 = – 40°C + 55°C , T5 = – 40°C + 60°C, T4 = – 40°C  + 70°C
Material: enclosure in GRP
IP rating: IP66/67
Enclosure Colour: Red ,Blue, Black, others colour on customer request
Lens: tempered glass colour Red, Yellow (Amber), Blue, Green, Clear.
Optional: lens guard in stainless steel
Power Supply: 12-48V DC/AC or 100-240V AC
Power Consumption: Xenon:2 Joule: 4W (Max); 5J: 10W (Max);10J: 15W (Max);15J: 20W(Max); 21J: 25W(Max); LED:5 W
Standard: EN/IEC 60079-0, EN/IEC 60079-1, EN/IEC 60079-31
Marking: Ex d IIC T4~T6 Gb,  Ex tb IIIC T135°C~T85°C, Ex II GD
Certification: Nemko 13 ATEX 1561X, IECEx NEM 13.0030X
Cable Entry: 4x M20 – M25**, 1/2″NPT**, 3/4″NPT** or other (specify)
Other: Telephone Initiated Function Available