EX STM 298 safety sensor

dispositif d'interverrouillage zone 2

EX STM 298

Ex security sensor for zone 2, 22

  • Ex zone 2 and 22
  • Metal enclosure
  • Wiring compartment
  • Spring-to-lock or power-to-lock principle

EX safety sensors are used to monitor the position of sliding, swivelling or removable protectors. For security functions according to DIN VDE 0660-209, the devices must only be used with a PL “e” protection door monitoring module according to EN ISO 13849-1 or up to SILCL 3 in accordance with EN 62061.

Characteristics

Applied standards: EN 60947-5-1, EN 60079-0, EN 60079-15, EN 60079-31, EN ISO 13849-1, EN ISO 14119
Enclosure: die-cast alloy
Switch type: type 2
Coding level: low coding
Degree of protection: IP 67 to IEC/EN 60529
B10d (10 % load): 12 million
Mechanical life: 1×106 operations
Ambient temperature: –20 °C … +75 °C
Degree of pollution: 3
Mounting position: any
Actuating speed V: max. 20 m/min
Extraction force (not locked): 30 N
Retention force: 20 N
Actuating force: max. 35 N
Operation cycles: max. 1200/h
Contact material: silver, gold flashed
Switching system: slow action, positive break NC contacts
Switching elements: 2 NC/2 NO, 3 NC/1 NO or 4 NC/2 NO contact, type Zb
Cable cross-section: 0.34 … 1.5 mm² (flexible/fixed)
Cable entry: 3 x M20 x 1.5 (incl. 1 cable gland)
Clamping range: 6,5 … 12 mm
Cable cross-section: 0.34 … 1.5 mm² (flexible/fixed)
Rated operating isolation voltage Ui: 50 V
Rated impulse withstand voltage Uimp: 2.5 kV
Conditional short-circuit current: 100 A
Switching voltage: min. 12 V at 10 mA
Utilisation category: AC-15; DC-13
Rated operating current/voltage Ie/Ue: 4 A/50 VAC; 4 A/24 VDC
Switching current: min. 1 mA at 24 V
Short-circuit protection: 4 A gG fuse (IEC 60269-1)
Conventional thermal current Ithe: 4 A
Solenoid operating voltage Us: 24 VDC (+10%/–15%)
Power consumption: 8 W
Switch-on time ED: 100 %
Locking force Fmax: Actuator straight: 3000 N, Actuator angled: 1500 N, Actuator flexible: 3000 N
Locking force FZh: (FZh = Fmax/1.3) = 2300 N
Impact energy: max. 7 J
Ex marking:  II3G Ex nR IIB T4 Gc X,  II3D Ex tc IIIC T110°C Dc X