Concepteur de solutions ATEX et industrielles
Contact : +33 (0) 4 88 78 21 81

EX AZM 415 safety sensor

serrure atex

EX AZM 415

Ex security sensor for zone 1, 21

  • Ex zone 1 and 21
  • Special version up to +90 °C ambient temperature for dust Ex zone 21 available (HU)
  • Spring-to-lock or power-to-lock principle
  • Two Ex switch inserts in one enclosure
  • Problem-free opening of stressed doors by means of bell-crank system
  • High locking force 3500 N
  • Ball catch
  • Wiring compartment
  • Special version only for dust Ex zone 22 available
  • Attention: Please state required international approvals with your order!

EX safety sensors are used to monitor the position of sliding, swivelling or removable protectors. For security functions according to DIN VDE 0660-209, the devices must only be used with a PL “e” protection door monitoring module according to EN ISO 13849-1 or up to SILCL 3 in accordance with EN 62061.

Characteristics

Applied standards: EN 60947-5-1, EN ISO 14119, EN 60079-0, EN 60079-1, EN 60079-7, EN 60079-18, EN 60079-31, EN ISO 13849-1
Enclosure: aluminium die-cast, enamel finish
Cover: steel, enamel finish
Actuator: metal zinc
Switch type: type 2
Coding level: low coding
Degree of protection: IP 67 to IEC/EN 60529; Ex AZM 415-TE, TEI, -FE: IP 64 to IEC/EN 60529
B10d (10 % load): 2 million
TM: max. 20 years
Switch insert: 2 x Ex 95
Contact material: silver
Switching system: slow action, positive break NC contacts
Switching elements: 2 NC/2 NO or 3 NC/1 NO contact
Connection: screw connection terminals
Cable cross-section: min. 0.2 mm² / AWG 24, max. 1.5 mm² / AWG 16
Cable entry: 2 x M20 x 1.5 (incl. 1 cable gland)
Clamping range: 7 … 12 mm
Rated impulse withstand voltage Uimp: 4 kV
Rated operating isolation voltage Ui: 250 V
Conventional thermal current Ithe: 6 A
Utilisation category: AC-15; DC-13
Rated operating current/voltage Ie/Ue: enabling/signalling contacts: 6 A/250 VAC; 0.25 A/230 VDC; direct-current solenoid: 0.08 A / 24 VDC ±10 %
Short-circuit protection: 6 A gG/gN fuse; direct-current solenoid: 2 A (slow blow)
Power consumption: max. 12 W (0.25 s)
Ambient temperature: T6: –20 °C … +40 °C; T5: –20 °C … +55 °C; Type HU: -20 °C … +90 °C
Operation cycles: max. 1200/h
Mechanical life: > 1 million operations
Locking force Fmax: 3500 N
Locking force of integrated ball catch: 50 – 200 N, adjustable
Impact energy: max. 7 J
Ex marking:  II 2G Ex demb IIC T6/T5 Gb,  II 2D Ex tb IIIC, T80 °C/T95 °C Db IP67/64, IECEx Ex demb IIC T6/T5 Gb, Ex tb IIIC T80 °C/T95 °C Db IP67/64
Type HU:  II 2D Ex tD A21 IP67 T130 °C, IECEx Ex tb IIIC T130 °C Db IP67
Type FE-HU:  II 2D Ex tD A21 IP64 T130 °C, IECEx Ex tb IIIC T130 °C Db IP64
Approvals: DMT 02 ATEX E 255 X, IECEx BVS 07.0018X
  Type HU: BVS 08 ATEX E 155 X, IECEx BVS 12.0013X