Concepteur de solutions ATEX et industrielles
Contact : +33 (0)4 88 78 21 81

Gas and Dust Classification

Classification of Gas and Vapor

Group of Gas
Group II (surface industries) comprises three subdivisions IIA , IIB and IIC defined according to the maximum experimental safe gap ( MESG ) for Exd envelopes or after the minimum ignition energy (EMI ) for intrinsically safe equipment . Most A2S products are designed for group IIC ( the most dangerous ) and can be used almost anywhere. However, some attention to explosion proof products (projectors, cabinets ) for which we generally have 2 separate solutions for groups IIB and IIC .

It should indeed use the ExdIIC solutions in the presence of hydrogen, acetylene, carbon disulphide or ethyl nitrate, and this because of the high cost of such equipment . The ExdIIB solutions are sufficient for all other types of gases or vapors effect.

Equipment using only the method of protection increased safety Exe does not appear Subdivision A , B or C because it can be used irrespective of the gas present.

Classes of temperature

Each gas has a self- ignition temperature of its own . When this temperature is reached, the gas ignites spontaneously, without sparks or arcing . The auto-ignition temperature should be considered as a limit not reached, either in normal operation or not. Standards define six classes of temperature (T1 to T6) corresponding to 6 maximum surface temperatures (450°C at 85°C).
Temperature class T6 is the strictest .

gas_temp

Classification of dust

Each type of dust has been studied in detail to determine their flammability characteristics (INRS Brochures/Guide silos … ) . The characteristic dust is their auto-ignition temperatures differ depending on whether the dust is in clouds or layers. Like many other parameters can change the auto-ignition values (particle size , humidity, température…), a calculation incorporating a safety margin must be made for each case.

  • In the case of dust cloud , the maximum surface temperature of the equipment shall not exceed two-thirds of the ignition temperature in degrees Celsius, the dust / air mixture (T1).
  • In the case of dust layers less than 5 mm, a safety factor of 75°C must be deduced from the temperature of self-ignition layer, in degrees Celsius , dust concerned (T2).

The choice of material will be done by taking the worst result.

The table below shows the results obtained for the most common dust :

dust_temp

Practical example:

On a manufacturing milk powder , the user wants to install a projector in ATEX zone 21 . The maximum surface temperature to be taken into account for the milk powder is 125 ° C. The PX04 projectors are suitable for zones 21 and 22 (category 2D). However a large portion of this range may be used as the maximum surface temperature is greater than 125 ° C. Only 70W versions (T90°C) and 150W (T115°C) can be installed in this area .

NOTE: ATEX certified products on the ” DUST “, the maximum surface temperature is shown in full in the dust marking on the label.

 

NOUS TROUVER

A2S (Advanced Safety Solutions) 350 Avenue JRGG de la Lauzière 31 Parc du Golf - CS 90519 13593 Aix en Provence Cedex 3

NOUS CONTACTER

Tél: +33 (0)4 88 78 21 81 Fax: +33 (0)4 42 16 35 09 E-mail : contact@a2s-antec.com